For flicker conformity tests according to the IEC 61000-3-3/-11 limits by using a power analyzer and artificial AC source, ZES ZIMMER manufactures and supplies the RI2415 reference impedance in single-phase (RI2415-SP) and three-phase (RI2415-TP) version. The RI2415 complies to the characteristics of the reference impedance specified in clause 6.4 of the 61000-3-3 standard and defined in IEC/TR 60725.
For seamless transition between flicker and harmonics testing the RI2415 includes a bypass switch to change between direct mode (EN61000-3-2 (Harmonics)) and impedance mode (EN61000-3-3/-11 (Flicker)).
The RI2415 provides a “Remote Control” connector to control the reference impedance with your power analyzer or any other automatic measurement system you use. A dedicated Sync cable is provided for the intended use with our power analyzer LMG600.