with printer and RS232-interface, CE-harmonic analysis (U,I DC till 40.) in pre-compliance, bench-type instrument in compact case,
best accuracy 0,11%, DC, 1Hz....20kHz
Direct voltage | 6 / 12,5 / 25 / 60 / 130 / 250 / 400 / 600Vtrms ; 1600Vpk |
Voltage sensor input | 0,12 / 0,25 / 0,5 / 1 / 2 / 4Vtrms ; 8Vpk |
Direct current | 0,6 / 1,2 / 2,5 / 5 / 10 / 16Atrms ; 60Apk |
16 safety laboratory leads |
Power supply cord |
LMG-CONTROL-BASIC datatransfer- and visualization software on enclosed CD |
LMG450-Manual |
Four independent current and voltage channels |
Isolated measurement inputs with extremely low capacitance and highest dynamics CMR and interference immunity |
Absolutely gap-free measuring process |
Harmonic and interharmonic analysis up to 99th harmonic resp. up to 99 interharmonics |
Analog and digital in/outputs |
Additional inputs for current sensors |
Auto-scaling current sensors compensated in phase and amplitude |
PC interfaces, memory-card slot, floppy drive |
Graphical colour display to show 4 to 8 measured values, wave form, diagrams of calculated values, bar charts and vector diagrams (fresnel diagrams) |
Ergonomic user friendly interface |
Formula editor |
LabVIEW driver |
For a 3-phase 3-wire system only the phase voltages U12, U23, U31 and the phase currents I1, I2, I3 are amenable to measurement. With the help of star-delta conversionline, voltages can be determined in the inaccessible phase voltages, converted into the associated active powers. In analogy, the phase currents can be converted into the "chained" currents. From the values thus calculated, all other variables, e.g. harmonics, are derived. Distortions and asymmetries of power and consumers are considered correctly. The use of an external artificial neutral point is thus superfluous, but such can be connected, if required, at any time, in case the associated disadvantages (e.g. increased power dissipation) are accepted.
All ZES ZIMMER power meters of the LMG series, the current sensors of PCT series and the voltage sensors of the HST series are carefully tested, adjusted and calibrated prior to shipment and are subject to strict quality controls.
ZES ZIMMER guarantees for a period of 24 months from first delivery that these products are free from defects in material or workmanship.
L45-O1 | IEEE488.2 Interfaces |
L45-O2USB | USB Interface (USB Driver download) |
L45-O3 | Process signal interface |
L45-O4 | Flicker meter acc. to EN61000-4-15 |
L45-O5 | Monitoring transients |
L45-O6 | Star to delta conversion |
L45-O7 | Memory extension for scope |
L45-O8 | Harmonics up to 99th |
L45-O12 | Special adjustment for active power measurement on transformers and other reactances ( Info Sheet) |
L45-O15 | Modification of voltage input: max. allowed trms value 1000V in biggest measuring range |
L45-O16 | MotorTorque-SOFT ( Info sheet) |
LMG-CONTROL-WA | WA-Analysis for LMG-CONTROL-B |
L45-Z00 | LMG450 manual, German or English |
L45-Z01 | 19"-rack mounting kit for LMG450 |
L45-Z02 | Carrying / tilting handle bar for LMG450 |
L45-Z04 | Carrying case for LMG450 and accessories |
L45-Z13 |
LMG450/500 master-slave cable, length 1m connection of 2 pcs. LMG450 via Sync inputs for simultaneous measuring of more than 4 phases Possible couplings: LMG450 <-> LMG450 LMG450 <-> LMG500 (1-8 phase) LMG500 (1-8 phase) <-> LMG500 (1-8 phase) |
L45-Z18 | Adapter for incremental speed sensor onto LMG450 measuring channel (HD15 sensor input) |
L45-Z318 | RS232 - Ethernet - converter, 10/100Mbit ( LAN driver download) |
LMG-Z-AMP | Artificial starpoint simulation for 3p-3w-systems |
L5-Z03 | Cable for coupling of process signal interfaces (analogue and digital) between two LMG450 and/or LMG95 |
L5-IOBOX-S | Adapter (also for DIN rail mount) from 25pol. SUB-D connector to screw cage connection for conductor cross sections up to 1,5mm x mm |
L5-IOBOX-F | Adapter (also for DIN rail mount) from 25pol. SUB-D connector to spring cage connection for conductor cross sections up to 1,5mm x mm |
L45-Z09 | Adapter BNC to HD15 for isolating current sensors with voltage output; without EEPROM |
L45-Z22 | Adapter safety plug to HD15 for isolating current sensors with current output up to 1,2Apk; EEPROM for storage of scaling |
For detailed information on accessories for measuring range extension and sensors refer to Datasheet Sensors and Special accessories for LMG95, LMG450 and LMG500.